DRZ30980
Dacor DRZ30980 Freezer Column Repair
Most common issues on this model
- Freezer temperature rising
- Ice maker water leaks
- Cooling Off mode
- Touch control response
The DRZ30980 is a current 30-inch column freezer with 17.6 cubic feet of space. It has a dedicated compressor and evaporator, an ice maker with two ice types and a hidden touch control at waist height.
A freezer whose temperature is climbing needs a quick, careful look, because food is at stake. We check the control mode first, since Cooling Off stops the cooling while the unit seems alive, then the door seal, the evaporator fan and the sealed system. For the ice maker, a leak usually traces to the fill tube or the water valve, so we follow the water from the line to the mold.
The hidden touch control can also cause trouble if it does not respond, and we test it before ordering a board. Parts are matched from the model and serial number on the label. We give a written price before work, and the work is covered by our 30-day workmanship warranty.
Key features
- Column freezer, 30 inches wide
- 17.6 cubic feet of space
- Ice maker that makes two kinds of ice
- Own compressor and evaporator
- Hidden touch control at waist height
My column freezer is getting warm. What should I do first?
Move food that is at risk to another freezer and call us. We check for Cooling Off mode, the door seal and the evaporator fan, then the sealed system.
Why is water leaking from the ice maker area?
A cracked fill tube, a loose connection or a valve that does not shut fully can leak. We trace the water path from the supply line to the mold and fix the leak point.
The touch control is hidden. How do you test it?
We confirm that it wakes and responds, then check its wiring to the main board. A control that works but reads the wrong temperature points to a sensor instead.
Book repair for your DRZ30980
Book online in about a minute, or give us a call. Same-day appointments are available inside the Loop on most days, and next-day service across the rest of Houston.