Dacor Gas and Induction Range Code C-22: Control Board Sensor Reading

The C-22 code shows up on the Dacor DOP30T940IS induction range and on the DOP48T960G gas range from the Transitional line. On the induction range, it means the sensor on the secondary control board reads open…

Medium · inspection needed
Code
C-22
Appliance
Range
Brand
Dacor
Warranty
30-day workmanship

What C-22 means

The C-22 code shows up on the Dacor DOP30T940IS induction range and on the DOP48T960G gas range from the Transitional line. On the induction range, it means the sensor on the secondary control board reads open or shorted while the range is operating. On the gas range, the code points to the temperature sensor on the main control board. Either way, the range is reading a board temperature it cannot trust, and you see C-22 on the display.

Common causes of C-22

  • The temperature sensor on the control board
  • The wiring or connector between the boards
  • The control board reading the sensor circuit
✓ One safe check you can try

1. Turn the mode knob to Off, wait a moment and start the range again. 2. If C-22 comes back, turn off the circuit breaker that feeds the range, leave it off for at least 30 seconds and switch it on again. 3. If the code is still there, stop using the range and call us to schedule a visit.

! Why to stop there
  • The code names a board sensor, but whether the sensor, a connector or the board is the cause shows only when we test the circuit.
  • Nothing starts until you have the price in writing, and the work is covered for 30 days.
  • If you know which model you have, the DOP30T940IS or the DOP48T960G, tell us when you book so we can bring the right parts.
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
C-22C-22 questions
Why is a control board sensor named in C-22?

The range sees a problem with a temperature sensor on a control board. On the induction range it is the secondary board, and on the gas range it is the main board's sensor.

Can I keep cooking if C-22 clears?

If it clears after a restart and stays away, you may. If it returns, the sensor circuit still has a problem, and we recommend a visit before it affects heating.

Do both ranges give C-22 for the same reason?

The code is shared, but the board differs. That is why we ask for your model before the visit.

Book a visit

Still seeing C-22?

A technician diagnoses it on site and gives you the price in writing before any work starts.